Amps to Watts Calculator

Convert electric current in amps (A) to electric power in watts (W). Select the current type — direct current (DC), AC single phase, or AC three phase with line-to-line or line-to-neutral voltage — enter the current, voltage and power factor, and press Calculate to get power in watts, kilowatts and milliwatts. Everything runs locally in your browser.

P(W) = I(A) × V(V) · scientific notation accepted, e.g. 5e3

Swap
STEP 1

Choose the current type

Pick Direct Current (DC) for batteries and electronics, Alternating Current (AC) - Single phase for household circuits, or Alternating Current (AC) - Three phase for motor and industrial circuits. Three phase also asks whether your voltage is line to line or line to neutral.

STEP 2

Enter current, voltage, power factor

Type the current and choose its unit (mA, A or kA), then the voltage and its unit (mV, V or kV). For AC modes also enter the power factor between 0 and 1 — use 1 for resistive loads like heaters and incandescent lamps. Scientific notation like 5e3 is accepted.

STEP 3

Press Calculate, read watts

Power appears in watts (W), kilowatts (kW) and milliwatts (mW) at once. Copy any of the three values to your clipboard, or press Reset to clear everything and start over.

How amps become watts

How do you convert amps to watts (DC)?
The power P in watts (W) is equal to the current I in amps (A), times the voltage V in volts (V): P(W) = I(A) × V(V). For example, 2 A at 12 V gives 2 × 12 = 24 W.
How do you convert amps to watts for AC single phase?
The power P in watts (W) is equal to the power factor PF times the phase current I in amps (A), times the RMS voltage V in volts (V): P(W) = PF × I(A) × V(V). For example, a 10 A load on 120 V at a power factor of 0.85 draws 0.85 × 10 × 120 = 1020 W.
How do you convert amps to watts for AC three phase?
With line-to-line voltage: P(W) = √3 × PF × I(A) × V(V) — 15 A at 480 V and PF 0.9 gives √3 × 0.9 × 15 × 480 ≈ 11223.7 W. With line-to-neutral voltage the factor 3 replaces √3: P(W) = 3 × PF × I(A) × V(V).
What power factor should I use?
Typical values: resistive loads such as heaters, ovens and incandescent lamps are about 1; fluorescent lamps about 0.95; induction motors about 0.85 at full load but only about 0.35 at no load; synchronous motors about 0.9. Do not use typical values for accurate calculations — measure or read the nameplate.
Quick reference at 120 V (DC or unity power factor)
0.1 A → 12 W · 0.3 A → 36 W · 0.5 A → 60 W · 1 A → 120 W · 5 A → 600 W · 10 A → 1200 W · 15 A → 1800 W. Power in kilowatts is watts ÷ 1000 and in milliwatts is watts × 1000.

Amps to watts table (120V)

Current (A)Voltage (V)Power (W)
0.1 amps120 volts12 watts
0.2 amps120 volts24 watts
0.3 amps120 volts36 watts
0.4 amps120 volts48 watts
0.5 amps120 volts60 watts
0.6 amps120 volts72 watts
0.7 amps120 volts84 watts
0.8 amps120 volts96 watts
0.9 amps120 volts108 watts
1 amp120 volts120 watts
2 amps120 volts240 watts
3 amps120 volts360 watts
4 amps120 volts480 watts
5 amps120 volts600 watts
6 amps120 volts720 watts
7 amps120 volts840 watts
8 amps120 volts960 watts
9 amps120 volts1080 watts
10 amps120 volts1200 watts

Typical power factor values

Do not use typical power factor values for accurate calculations.

DeviceTypical power factor
Resistive load1
Fluorescent lamp0.95
Incandescent lamp1
Induction motor full load0.85
Induction motor no load0.35
Resistive oven1
Synchronous motor0.9